Horn Auto-Select Report

Experimental candidates: not validated recommendations

Predictions are experimental. Driver suitability and the exterior model require independent validation. The observer integrates the nonuniform axisymmetric aperture velocity in an infinite baffle. Raw horn plots show mouth-plane pressure. Legacy inputs contain mouth-plane levels only.

Drive: 2.83 V RMS. Observer: 1.0 m on axis from mouth plane. Maximum target-band ripple: 6.0 dB. Acoustic CAD describes air volume, not manufacturing walls.

Acoustic models used: lossless / modal_baffled. Scores within 0.02 are near-ties for comparison; physical uncertainty remains unquantified.

Target: 800 Hz to 1600 Hz  |  Throat radius: 0.0127 to 0.0500 m (search range)  |  Mouth: 0.0478 to 0.0887 m (search range)  |  Length: 0.107 to 0.214 m (search range)  |  Horns: auto_cd_0221, auto_exp_0057, auto_sca_0189, refine_cd_0000, refine_cd_0001  |  Generated: 2026-11-17 04:29 UTC

Candidates scored
25
Top shown
5
Best score
0.791
Best extension (oct)
+1.38
Best mean output
104.2
Lowest ripple
2.1

How to read this report

  1. Every number is a linear model prediction (FEM horn, lumped driver). Treat it as an experimental starting point to build and measure, not a validated recommendation.
  2. Rank 1 is the highest score among designs that meet the hard limits (ripple at most 6 dB in 800 to 1600 Hz, compression ratio, size and driver limits). A design whose limits are exceeded only because of an estimated front chamber is still ranked, with the exceeded limits listed in its Front chamber column (item 6). The score formula and weights are stated under Rankings. Scores within 0.02 are near ties.
  3. Each candidate is named horn ID + driver ID. Plot legends use the same #rank ID, so every curve maps to one ranking row.
  4. Levels are on axis at 1 m for 2.83 V RMS. |Ze| is the electrical impedance an amplifier sees, in ohms. The throat impedance plot is acoustic, horn only.
  5. Build from the top candidate section: the profile CSV gives the air passage wall radius against axial position in mm (z = 0 at the throat), and the STEP file is the same air volume at true size. Add your own wall thickness. File paths are relative to the folder that holds this report.
  6. The front chamber column states the chamber between diaphragm and throat that the prediction used: supplied, estimated from the cone geometry, or none. Estimated chambers are flagged and do not reject a design on their own.
  7. The rejection table counts why other designs failed and how close they came.

Top candidate: build data

Candidate
#1 refine_cd_0001 + 18sound-6nmb420 (18Sound 6NMB420)
Throat
radius 36.1 mm
Mouth
radius 88.7 mm
Length
117.9 mm
Profile
cd
STEP file (acoustic air volume, mm; path relative to this report)
../refinement/refine_cd_0001.step
Profile CSV (z_mm, r_mm)
profile_01_refine_cd_0001.csv
Front chamber assumed
estimated 139.4 cm3 (cone air, flat adapter plate)
CandidateFront chamber assumedProfile CSVSTEP
#1 refine_cd_0001 + 18sound-6nmb420estimated 139.4 cm3 (cone air, flat adapter plate)profile_01_refine_cd_0001.csv../refinement/refine_cd_0001.step
#2 auto_cd_0221 + 18sound-6nmb420estimated 139.4 cm3 (cone air, flat adapter plate)profile_02_auto_cd_0221.csv../geometry/horn_auto_cd_0221.step
#3 auto_exp_0057 + 18sound-6nmb420estimated 139.4 cm3 (cone air, flat adapter plate)profile_03_auto_exp_0057.csv../geometry/horn_auto_exp_0057.step
#4 refine_cd_0000 + 18sound-6nmb420estimated 139.4 cm3 (cone air, flat adapter plate)profile_04_refine_cd_0000.csv../refinement/refine_cd_0000.step
#5 auto_sca_0189 + 18sound-6nmb420estimated 139.4 cm3 (cone air, flat adapter plate)profile_05_auto_sca_0189.csv../geometry/horn_auto_sca_0189.step

Design Summary

Target frequency band
800 to 1600 Hz
Throat radius range
0.0127 to 0.0500 m
Mouth radius
0.0478 to 0.0887 m (optimized)
Length
0.1072 to 0.2144 m (optimized, λ/4 to λ/2)
Ideal mouth radius
0.0682 m (from c₀/2πflow)
Simulation freq range
400 to 2263 Hz (1.0 octave below, 0.5 above)
Profiles
7 (conical, exponential, hyperbolic, tractrix, OS, axially scaled tractrix, CD)
Geometry candidates
230

LEM Prescreening

Candidates evaluated (LEM/Webster)
230
Driver-horn pairs scored
1150
Candidates passed to FEM
3

Horn Geometry

Cd (refine_cd_0001): throat 36.1, mouth 88.7, L 118 mm
Cd (auto_cd_0221): throat 36.1, mouth 88.7, L 107 mm
Exponential (auto_exp_0057): throat 36.1, mouth 88.7, L 107 mm
Cd (refine_cd_0000): throat 36.1, mouth 79.8, L 107 mm
Scaled_tractrix (auto_sca_0189): throat 36.1, mouth 88.7, L 161 mm

Rankings

Score. score = w_sensitivity*clip((L_mean-60)/60,0,1) + w_ripple*clip(1-ripple/12,0,1) + w_extension*clip(0.5+E/2,0,1) + w_size*clip(0.5-log2(V/V_ref)/8,0,1); weights sum to 1; infeasible designs score 0. L_mean: log-frequency mean level over the target band (dB); ripple: its peak-to-peak range (dB); E = log2(f_low/f3_low)+log2(f3_high/f_high) (octaves), f3 3 dB below L_mean searched outward from the band edges over the full sweep; V = pi*r_mouth^2*L; V_ref = pi*(c/(2*pi*f_low))^2*c/(4*f_low).

Weights (pipeline default): sensitivity 0.625, ripple 0.250, extension 0.125, size 0.000. 1 dB less ripple is worth 2.00 dB of sensitivity; 1 octave more extension is worth 6.00 dB; halving the horn volume is worth 0.00 dB.

Constraints: max_ripple_db 6.0 (pipeline default); max_compression_ratio 10.0 (pipeline default); min_output_db None (not set).

Geometry bounds: throat_radius_m: from driver prescreen 0.0127 to 0.0500; mouth_radius_m: heuristic range 0.0478 to 0.0887; length_m: heuristic range 0.1072 to 0.2144.

Refinement: 2 new geometries from auto_cd_0221 (best feasible).

Front chamber: Levels and scores include each driver's front chamber. A cone driver without chamber data gets a geometric estimate (front_chamber_estimated); a constraint that fails only with that estimate is listed in estimated_chamber_reasons and flagged, not rejected. A supplied volume, including 0, is used as given.

#Candidate ID (horn + driver)ManufacturerModelTypeSizePower (W)Profile Throat R (mm)Mouth R (mm)Length (mm) Score Extension (oct; ≥ = lower bound)Ripple (dB)Mean output (dB)f3 range (Hz; ≤/≥ = sweep bound)Peak (dB)Front chamberEvidence status
1refine_cd_0001 + 18sound-6nmb42018Sound6NMB420cone6.5in200Cd36.188.7117.90.791 (near tie)+1.062.1
est. chamber; 3.2 without
104.1485 to 2024106.4139 cm³ estimatedfeasible, evidence gaps
2auto_cd_0221 + 18sound-6nmb42018Sound6NMB420cone6.5in200Cd36.188.7107.20.785 (near tie)+0.992.4
est. chamber; 3.2 without
104.1512 to 2033106.1139 cm³ estimatedfeasible, evidence gaps
3auto_exp_0057 + 18sound-6nmb42018Sound6NMB420cone6.5in200Exponential36.188.7107.20.772 (near tie)+0.882.7
est. chamber; 2.9 without
104.2524 to 1932106.6139 cm³ estimatedfeasible, evidence gaps
4refine_cd_0000 + 18sound-6nmb42018Sound6NMB420cone6.5in200Cd36.179.8107.20.758+0.993.4
est. chamber; 4.3 without
103.6496 to 1964106.7139 cm³ estimatedfeasible, evidence gaps
5auto_sca_0189 + 18sound-6nmb42018Sound6NMB420cone6.5in200Scaled_tractrix36.188.7160.80.752+1.383.7
est. chamber; 2.3 without
103.6414 to 2157107.9139 cm³ estimatedfeasible, evidence gaps

Rejected designs

10 driver-horn pairs were rejected at the FEM stage. A pair can fail more than one limit. Excess is how far past the limit it was; the closest miss is the smallest.

ReasonMeaningCountClosest missLargest excessUnit
outside_driver_usable_bandTarget band outside the driver's usable band10n/an/an/a
driver_excursion_exceededExcursion above Xmax at the drive voltage50.060.06mm

Estimated observer output: top candidates

Coupled SPL comparison

Electrical impedance, excursion and group delay of the top candidates

|Ze| in ohms as the amplifier sees it; peak excursion against Xmax (dotted); system group delay on axis with the straight-line time of flight removed. Per-frequency values are in the coupled_NN CSV files.

Electrical impedance, excursion and group delay

Horn only, ranked horns

Horn-only SPL of the ranked horns

Horn-only acoustic throat impedance & phase

Throat impedance
Phase response

Directivity (experimental, infinite baffle)

Far-field pattern from the solved axisymmetric mouth velocity, relative to the axis, for an infinite rigid baffle. A finite baffle or cabinet changes it by several dB, and it has not been compared with a measured polar. Use it to compare profiles, not as a coverage claim.

Beamwidth against frequency

Pre-Screened Drivers

ManufacturerModelFs (Hz)Re (Ω)BL (T·m) Sd (cm²)Mms (g)Le (mH)QmsQesQtsEBP
18Sound6NMB4201105.39.0130.008.500.102.70.380.33289
CelestionAF3010 (16 ohm)12910.56.033.183.550.266.10.840.74153
CelestionTF0512HE855.46.778.548.890.289.20.570.54149
PeerlessDFM-2535R00-087466.54.010.900.500.035.70.970.83769
PeerlessDFM-2544R00-087846.12.116.200.300.042.02.031.01386