Predictions are experimental. Driver suitability and the exterior model require independent validation. The observer integrates the nonuniform axisymmetric aperture velocity in an infinite baffle. Raw horn plots show mouth-plane pressure. Legacy inputs contain mouth-plane levels only.
Drive: 2.83 V RMS. Observer: 1.0 m on axis from mouth plane. Maximum target-band ripple: 6.0 dB. Acoustic CAD describes air volume, not manufacturing walls.
Acoustic models used: lossless / modal_baffled. Scores within 0.02 are near-ties for comparison; physical uncertainty remains unquantified.
Target: 800 Hz to 1600 Hz | Throat radius: 0.0127 to 0.0500 m (search range) | Mouth: 0.0478 to 0.0887 m (search range) | Length: 0.040 to 0.100 m (search range) | Horns: auto_cd_0214, auto_con_0025, auto_exp_0059, refine_conical_0000, refine_conical_0001 | Generated: 2026-11-17 08:32 UTC
horn ID + driver ID. Plot legends use the same #rank ID, so every curve maps to one ranking row.../refinement/refine_conical_0001.stepprofile_01_refine_conical_0001.csv| Candidate | Front chamber assumed | Profile CSV | STEP |
|---|---|---|---|
| #1 refine_conical_0001 + 18sound-6nmb420 | estimated 139.4 cm3 (cone air, flat adapter plate) | profile_01_refine_conical_0001.csv | ../refinement/refine_conical_0001.step |
| #2 auto_con_0025 + 18sound-6nmb420 | estimated 139.4 cm3 (cone air, flat adapter plate) | profile_02_auto_con_0025.csv | ../geometry/horn_auto_con_0025.step |
| #3 auto_cd_0214 + 18sound-6nmb420 | estimated 139.4 cm3 (cone air, flat adapter plate) | profile_03_auto_cd_0214.csv | ../geometry/horn_auto_cd_0214.step |
| #4 auto_exp_0059 + 18sound-6nmb420 | estimated 139.4 cm3 (cone air, flat adapter plate) | profile_04_auto_exp_0059.csv | ../geometry/horn_auto_exp_0059.step |
| #5 refine_conical_0000 + 18sound-6nmb420 | estimated 139.4 cm3 (cone air, flat adapter plate) | profile_05_refine_conical_0000.csv | ../refinement/refine_conical_0000.step |
Score. score = w_sensitivity*clip((L_mean-60)/60,0,1) + w_ripple*clip(1-ripple/12,0,1) + w_extension*clip(0.5+E/2,0,1) + w_size*clip(0.5-log2(V/V_ref)/8,0,1); weights sum to 1; infeasible designs score 0. L_mean: log-frequency mean level over the target band (dB); ripple: its peak-to-peak range (dB); E = log2(f_low/f3_low)+log2(f3_high/f_high) (octaves), f3 3 dB below L_mean searched outward from the band edges over the full sweep; V = pi*r_mouth^2*L; V_ref = pi*(c/(2*pi*f_low))^2*c/(4*f_low).
Weights (pipeline default): sensitivity 0.625, ripple 0.250, extension 0.125, size 0.000. 1 dB less ripple is worth 2.00 dB of sensitivity; 1 octave more extension is worth 6.00 dB; halving the horn volume is worth 0.00 dB.
Constraints: max_ripple_db 6.0 (pipeline default); max_compression_ratio 10.0 (pipeline default); min_output_db None (not set).
Geometry bounds: throat_radius_m: from driver prescreen 0.0127 to 0.0500; mouth_radius_m: heuristic range 0.0478 to 0.0887; length_m: heuristic range with a user limit 0.0400 to 0.1000.
Size compromise: The size caps are below the ka = 1 mouth and quarter-wave sizing rules for 800 Hz. By those rules of thumb, horn loading is expected to weaken below about 858 Hz, 0.10 octaves above the target. This is a sizing rule, not a prediction. The best ranked design's predicted f3_low is 649 Hz, at or below 800 Hz, so the model prediction does not show this shortfall.
Refinement: 2 new geometries from auto_con_0025 (best feasible).
Front chamber: Levels and scores include each driver's front chamber. A cone driver without chamber data gets a geometric estimate (front_chamber_estimated); a constraint that fails only with that estimate is listed in estimated_chamber_reasons and flagged, not rejected. A supplied volume, including 0, is used as given.
| # | Candidate ID (horn + driver) | Manufacturer | Model | Type | Size | Power (W) | Profile | Throat R (mm) | Mouth R (mm) | Length (mm) | Score | Extension (oct; ≥ = lower bound) | Ripple (dB) | Mean output (dB) | f3 range (Hz; ≤/≥ = sweep bound) | Peak (dB) | Front chamber | Evidence status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | refine_conical_0001 + 18sound-6nmb420 | 18Sound | 6NMB420 | cone | 6.5in | 200 | Conical | 36.1 | 88.7 | 63.0 | 0.789 (near tie) | ≥+0.80 | 1.4 est. chamber; 1.3 without | 103.7 | 649 to ≥2263 | 104.5 | 139 cm³ estimated | feasible, evidence gaps |
| 2 | auto_con_0025 + 18sound-6nmb420 | 18Sound | 6NMB420 | cone | 6.5in | 200 | Conical | 36.1 | 88.7 | 70.0 | 0.789 (near tie) | ≥+0.86 | 1.7 est. chamber; 1.5 without | 103.8 | 621 to ≥2263 | 104.7 | 139 cm³ estimated | feasible, evidence gaps |
| 3 | auto_cd_0214 + 18sound-6nmb420 | 18Sound | 6NMB420 | cone | 6.5in | 200 | Cd | 36.1 | 88.7 | 100.0 | 0.781 (near tie) | +0.96 | 2.5 est. chamber; 2.9 without | 104.2 | 532 to 2066 | 105.9 | 139 cm³ estimated | feasible, evidence gaps |
| 4 | auto_exp_0059 + 18sound-6nmb420 | 18Sound | 6NMB420 | cone | 6.5in | 200 | Exponential | 36.1 | 88.7 | 100.0 | 0.768 | +0.84 | 2.8 est. chamber; 2.5 without | 104.3 | 546 to 1959 | 106.4 | 139 cm³ estimated | feasible, evidence gaps |
| 5 | refine_conical_0000 + 18sound-6nmb420 | 18Sound | 6NMB420 | cone | 6.5in | 200 | Conical | 36.1 | 79.8 | 70.0 | 0.759 | ≥+0.88 | 3.0 est. chamber; 2.4 without | 103.7 | 615 to ≥2263 | 105.3 | 139 cm³ estimated | feasible, evidence gaps |
10 driver-horn pairs were rejected at the FEM stage. A pair can fail more than one limit. Excess is how far past the limit it was; the closest miss is the smallest.
| Reason | Meaning | Count | Closest miss | Largest excess | Unit |
|---|---|---|---|---|---|
outside_driver_usable_band | Target band outside the driver's usable band | 10 | n/a | n/a | n/a |
driver_excursion_exceeded | Excursion above Xmax at the drive voltage | 5 | 0.06 | 0.07 | mm |
|Ze| in ohms as the amplifier sees it; peak excursion against Xmax (dotted); system group delay on axis with the straight-line time of flight removed. Per-frequency values are in the coupled_NN CSV files.
Far-field pattern from the solved axisymmetric mouth velocity, relative to the axis, for an infinite rigid baffle. A finite baffle or cabinet changes it by several dB, and it has not been compared with a measured polar. Use it to compare profiles, not as a coverage claim.
| Manufacturer | Model | Fs (Hz) | Re (Ω) | BL (T·m) | Sd (cm²) | Mms (g) | Le (mH) | Qms | Qes | Qts | EBP |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 18Sound | 6NMB420 | 110 | 5.3 | 9.0 | 130.00 | 8.50 | 0.10 | 2.7 | 0.38 | 0.33 | 289 |
| Celestion | AF3010 (16 ohm) | 129 | 10.5 | 6.0 | 33.18 | 3.55 | 0.26 | 6.1 | 0.84 | 0.74 | 153 |
| Celestion | TF0512HE | 85 | 5.4 | 6.7 | 78.54 | 8.89 | 0.28 | 9.2 | 0.57 | 0.54 | 149 |
| Peerless | DFM-2535R00-08 | 746 | 6.5 | 4.0 | 10.90 | 0.50 | 0.03 | 5.7 | 0.97 | 0.83 | 769 |
| Peerless | DFM-2544R00-08 | 784 | 6.1 | 2.1 | 16.20 | 0.30 | 0.04 | 2.0 | 2.03 | 1.01 | 386 |